Hydraulic Mechanical Impact Ollision Table High-impact Acceleration Testing Machine
Applications:
Primarily used for high-impact acceleration testing of test specimens to assess their resistance to impact damage. Commonly used for environmental testing of electronic components, electronic circuit boards, and batteries, this test equipment complies with the shock testing requirements of the “Basic Environmental Testing Specification for Electrical and Electronic Products Ea: Shock Test Method,” “IEC68-2-27, Test Ea: Shock,” and “MIF-STD202F.”
System Principle:
The HJ-CJ-200 impact test table features customizable dimensions. Its structure is meticulously designed through finite element optimization analysis, resulting in exceptional structural strength and high frequency response. It can withstand high-acceleration impact tests, achieving an acceleration duration of 0.5ms. The impact’s semi-sine waveform meets test specifications. It also features a built-in secondary impact protection device and a high-efficiency vibration damping mechanism. The impact height can be digitally set and automatically executed.
| Model: | HJ-CJ-200 |
| Maximum Load: | 200 kg (including fixture) |
| Table Dimensions: | 500 mm x 500 mm |
| Peak Shock Acceleration Range: | Half-sine wave: 100 to 1000 m/s² |
| Pulse Duration: | Half-sine wave: 2.5 to 20 ms |
| Shock Waveform: | Half-sine waveform |
| Maximum Impact Drop Height: | 1.5 m |
| Wave velocity difference | a) When the pulse duration is ≤ 3ms, the peak acceleration tolerance is ±20%; |
| The pulse duration tolerance is ±15%; | |
| When the pulse duration is > 3ms, the waveform tolerance should be within the specified range. | |
| Speed Variation: | ±15% tolerance |
| Secondary Impact Prevention Device: | Equipped with hydraulic brake |
| Impact Platform Dimensions: | (1000×500×2600mm) (Customizable according to actual specifications) |
| Impact Platform Weight (Approximate): | 500kg |
| Power Consumption: | 2kVA |
| Working conditions: | Power supply voltage: 220V ± 10% AC 50Hz |
| Ambient temperature: 0°C-40°C | |
| Relative humidity: ≤90% (25°C) | |
| Ambient environment: Free of corrosive media, dry and well-ventilated | |
| Electromagnetic interference and strong vibration sources that may affect normal operation | |
| Comply with standards: | GJB150, GJB360, GB2423, etc. requirements |